29
8.1 WATER CONDENSER
1) Disconnect the machine.
2) Disconnect the water inlet or close the tap.
3) Disconnect the water inlet and outlet from the condenser.
4) Prepare a 50% solution of phosphoric acid and distilled or demineralised water (or a suitable product to clean
the water condenser circuit).
5) Make it circulate through the condenser. (The mixture is more effective when hot - between 35º and 40º C-)
Do not use hydrochloric acid.
8.2 AIR CONDENSER
1) Disconnect the machine.
2) Disconnect the water inlet or close the tap.
3) Clean with the help of a vacuum cleaner, non-metallic brush or low-pressure air.
8.3 EVAPORATOR / WATER CONTAINER
8.3.1 CLEANING INSTRUCTIONS
1.
We recommend using the cleaning product Calklin. Prepare a solution with 50% phosphoric acid and distilled
water. Do not use hydrochloric acid. Remove the rear panel to access the production containers. Remove the
cover attached to the pump to access the interior of the container where you should pour the previously
prepared mixture. The mixture is more effective if the water is between 35ºC and 40ºC.
2.
Washing cycle: Press the button
and the power button
for 3 seconds. The pumps will recirculate
the mixture through the evaporators and containers. The compressor and other components will remain
disconnected during this cycle.
3.
Let the solution act for 10 minutes.
4.
After 10 minutes, halt the washing cycle pressing the power button
and the machine will stop.
1
Summary of Contents for 400 A
Page 1: ...INSTRUCTIONS MANUAL Sold separated...
Page 10: ...6 MACHINE STACKING DIAGRAM...
Page 12: ...8 3 7 THERMOSTAT CONNECTIONS Machine stacking kit...
Page 30: ...26 6 4 WATER AND DRAINAGE CONNECTIONS ICE CHUTE...
Page 60: ......
Page 61: ......
Page 62: ......
Page 63: ......
Page 64: ......
Page 65: ......
Page 66: ......
Page 67: ......