Struck Documentation
SIS8300-KU
MTCA.4 Digitizer
Page 36 of 92
7.5.8 ADC Sample Control register
#define SIS8300_SAMPLE_CONTROL_REG
0x11
ADC channels can be disabled from storing data to memory by setting the corresponding
disable bit in this register.
Bit
write
31
..
..
12
11
Enable external Trigger
10
Enable internal Trigger
9
Disable Sampling Ch10
8
Disable Sampling Ch9
7
..
6
..
5
..
4
..
3
..
2
Disable Sampling Ch3
1
Disable Sampling Ch2
0
Disable Sampling Ch1
The power up default value is 0x0