16
Push the appliance back into the fireplace, centralise and pull the loose cables through the holes into
the firebox, thread the cable tensioners onto the cable as shown, with the nuts screwed down close to
the tensioner head. Slide the screwed nipple through the box and pull cable taut and tighten pinch
screw on to the cable.
Adjust tensioner using a suitable spanner to pull the cable tight into position, to allow an even seal
around the edge of the fire, visually inspect the seal and reseat if necessary.
Pinch screw
Tension nut
Through holes at the
top of the fire box
Through
Screw eyes
Through Screw eye at
the bottom and
through the 2 holes
near base of the firebox