43
corresponding to the workbench until 1000mm is displayed as the standard
measured value. At that time, the displayed value at the display is
999.98mm.
Method 1: Manually input the correction system. Calculate with the
following formula:
Correction factor S = (L-L')/(L/1000) mm/m
L---Actual measured length. Unit: mm
L'---Displayed value at the display. Unit: mm
S---When the correction factor mm/m is "+", lengthening is
indicated; when the correction factor mm/m is "-", shortening is
indicated.
Compensation scope: -1.500 mm/m~+1.500 mm/m
The actually-measured length of the machine tool workbench is
1000, while the finally displayed value at the display is 999.98.
S=(1000-999.98)/(1000/1000)=0.02 mm/m
After the correction factor is got through calculation, press the axis key.
Press
key. Then the setting interface is displayed.
Method 2: Automatic calculation correction system
1. The interface for setting the linear
compensation tale is displayed. Move the
cursor to the “automatic setup” area at X axis.
2. Move the X-axis grating rule on the
workbench until 1000mm is displayed as
The standard measured value. At that time,
999.98mm is the displayed value at the display.
3. Press the
button. The error correction is completed.