9
2.9 Setting the Combined Axis Display
During machine tool design, the case that two grating rulers are
installed in the same axis direction may occur, requiring to display the
positions of actually processed contact points, and the counting values of
two grating rulers need to be displayed in combination. The combination
setting can meet this requirement.
The combination has the following modes:
1) No combination: The value on each axis is displayed separately.
2
) Y=Y+Z: The displayed value on axis Y is equal to the value on axis
Y and the value on axis Z.
Factory default: no combination
For example: Set the combination
mode to Y=Y+Z
1) On the interface of system
parameter setting,
Press the
or
key until the cursor moves to
to the option field of combination.
2) Press the “+” or “-” function key to switch the combination mode to
Y=Y+Z.
3) Press the “Save” function key to save the modification.
4) Press the “Exit” function key to quit the interface of system parameter
setting.
2.10 Setting the Display of Dithering Elimination
During grinding, the vibration of the grinder makes what’s on the display
change repeatedly and quickly, discomforting the operator visually. The display
has a dithering elimination function which prevents what’s on the display from
changing quickly and causing visual confusion when the grinder vibrates.
Factory default: 0 (disabled)
For example: Set dithering elimination to 1 (enabled).
1) On the interface of system parameter setting,
Summary of Contents for SDS 2-3VA
Page 1: ...LCD DIGITAL DISPLAY SDS 2 3VA OPERATION MANUAL...
Page 6: ...1...