5
Function Setting
No
Item
Range
Default
Remarks
1
Mode
Cool
Heat
1. When the water tank is unavailable, then only
“
Cool
” and “
Heat
” are available.
2. For the heating only unit, only "Heat" mode, “Hot
water”, and “Heat + hot water” are available.
3. It is defaulted to be “Heat” for the heat pumps and
heating only units and “Cool” for mini chillers.
Heat
Hot water
Cool + Hot water
Heat + Hot water
2
Fast hot water
On/Off
Off
1. When the water tank is unavailable, it will be
reserved.
3
Cool + hot water
Cool/Hot water
Cool
1. When the water tank is available, it will be
defaulted to be “
Hot water
”; when unavailable, it will
be reserved.
4
Heat + hot water
Heat/Hot water
Heat
1. When the water tank is available, it will be
defaulted to be “
Hot water
”; when unavailable it will
be reserved.
5
Quiet mode
On/Off
Off
/
6
Quiet timer
On/Off
Off
/
7
Weather depend
On/Off
Off
/
8
Weekly timer
On/Off
Off
/
9
Holiday release
On/Off
Off
10
Disinfection
On/Off
Off
When the water tank is unavailable, it will be reserved
The disinfection date ranges from Monday to Sunday.
Saturday is defaulted.
23:00. The disinfection time ranges from
00:00~23:00. 23:00 is defaulted.
11
Clock timer
On/Off
Off
/
12
Temp. timer
On/Off
Off
/
13
Emergen. mode
On/Off
Off
/
14
Holiday mode
On/Off
Off
/
15
Preset mode
On/Off
Off
/
16
Error reset
/
/
Some error can be cleared only when it has been
reset manually.
17
WiFi reset
It is used to reset the WiFi.
18
Reset
/
/
It is used to reset all user parameter setting.
2.2.1 Mode
[Operation Instructions]
At the function setting page with the unit turned off, by touching “
Mode
”, it will go to the mode setting page,
where desired mode can be selected. Then by touching “
OK
” this setting will be saved and the display panel will
back to the function setting page.