10
[Notes]
● When “
Clock timer
” has been set and “
Hot water
” mode is involved, in this case, if “
Water tank
” is changed
to “
Without
”, “
Hot water
” will be automatically switched to “
Heat
”, and “
Cool/Heat + Hot water
” will be switched to
“
Cool/Heat
”.
● When “
Weekly timer
” and “
Clock timer
” have been set at the same time, the priority will be given to the
former.
● When the water tank is available, “
Heat
”, “
Cool
”, “
Hot
”, ‘
Heat + Hot water
”, and “
Cool + Hot water
” are
allowed; however, when the water tank is unavailable, only “
Heat
” and “
Cool
” are allowed.
● When the end time is earlier than the start time, this setting is invalid.
● Water tank temperature can be set only when “
Hot water
” is involved in the operation mode.
● The setting of “
Clock timer
” only works once. If this setting is needed again, it should be set again.
● It will be deactivated when the unit is turned on manually.
● When “
Weather depend
” has been activated and the mode for “
Clock timer”
is set to “
Hot water
”, “
Weather
depend
” will be deactivated when the setting mode has been switched.
● This function will be memorized upon power failure.
2.2.11 Temp. Timer
At the function setting page, access to the “
Temp.timer
” setting page.
At the “
Temp.timer
” setting page, it can be set to “
On
” or “
Off
”.
Select “
Period 1
”/”
Period 2
” and a window will pop up, where time period can be set. Then select "
WT-Heat1/
WT-Cool 1/2
” and also a window will pop up where temperature can be set.