C18 - AC power to the Transceiver Unit
This cable is included in the delivery. It is used for the mains supply
to the Transceiver Unit. The mains power can be 115 or 230 Vac.
Observe the following procedure for the connection of the mains
power.
1
Pull out the main power input connector
P201
on the
Transceiver Unit’s Power Control Unit.
→
Refer to figure 25 for location of the connector.
Figure 25 Power
units in the SH80
Transceiver Unit
F206
8A
F204
5A
F202
5A
SLOW
BLOW
SLOW
BLOW
SLOW
BLOW
F205
8A
F203
5A
F201
5A
GND
24V
80V
5V
-5.8V
5.8V
12V
24V
STAND
BY
ON/OFF
RELAY
HV-
POWER
TRIPLE-
POWER
12V
POWER
SUPPLY
SERVICE
OFF
NORMAL
P201
L203
L204
S201
L205
MAINS INPUT
115/230V AC
(C
D
60
71
B
)
S201
Service
switch
P201
AC input
2
Set the service switch
S201
on the Power Control Unit to the
Off
(middle) position.
3
Connect the mains power cable to a normal mains outlet in
the sonar room.
- If the delivered cable connector does not fit use an
adaptor, or replace with a suitable plug.
→
For connection of the mains cable, refer to figure 22 on page 64.