Start-up procedures
103
851-164300 / C
Checking the bridge functions
Note
This procedure must be performed simultanously with the next
procedure;
Checking the sonar room functions
.
The instructions marked
Sonar room:
are performed in the sonar
room.
1
Check that the depth under the keel is sufficient to safely
lower the transducer.
2
Start the sonar.
a
Press the
Power
button on the Sonar Operating Panel for
approximately two seconds.
b
Check that the green LED next to the
Power
button starts
blinking.
c
Observe that the sonar picture is displayed after
approximately two minutes.
d
Check that the green LED next to the
Up
button
illuminates.
e
Check that the upper button in the
Status
menu shows
Transducer: UP.
f
If communication exists, notify the sonar room to
perform the next step.
3
Sonar room:
Press the black button marked
1
on the motor
overload switch
S301
in the Motor Control Unit.
4
Sonar room:
Set the hoist / lower switch
S302
in the Motor
Control Unit to
Remote.
5
Lower the transducer to its middle position.
a
Press the
Middle
button in the
Main Sw
field on the
Operating Panel to lower the transducer to its middle
position.
b
Check that the LED next to the
Middle
button starts to
flash, and that the audible signal indicates transducer
movement.
c
When middle position has been reached, check that the
LED next to the
Middle
button illuminates continuously,
that the audible signal stops, and that the upper button in
the
Status
menu shows
Transducer: MIDDLE
.
6
Lower the transducer to its lower position.
a
Press the
Down
button to lower the transducer to the
lower position.
b
Check that the LED next to the
Down
button starts to
flash, and that the audible signal indicates transducer
movement.