Testing the peripheral equipment
129
851--164300 / C
10.6 Echo sounder
The SH80 Processor Unit can read the depth information from an
echo sounder on standard NMEA 0183 RS-232 serial line format.
Observe the following procedure to test the echo sounder interface.
1
Access the
I/O Setup
menu.
→
A procedure for this is located on page 121.
2
Select
Sensors
in the
I/O Setup
menu, then
Echo sounder
,
and finally
EchoNmea
3
Observe the
Sensor Config
submenu appears at the bottom
of the menu field.
4
Check that the settings in the
Sensor Config
submenu
correspond to your requirements for the serial line.
5
Press
Close
to exit the
Sensor Config
menu.
6
Select
Bow up/Vertical
mode.
7
Check that the depth readout in the
Catch Data
page
corresponds to the depth readout on the echo sounder.