Operating manual

1 Preface

1.1 Foreword to this manual

This manual is intended for professional operation, installation 
and maintenance by trained, knowledgeable and qualified 
personnel (such as mechatronics engineer or electrician) and /
 or qualified personnel who know how to install electrical equip-
ment.

Read this operating manual carefully and pay particular atten-
tion to the hazard warnings. Store this operating manual for 
future reference / maintenance. Please pay close attention to 
the terminal assignment, the minimum and maximum perfor-
mance data (see “Technical Data”) and the installation instruc-
tions. Incorrect use or improper operation / mounting may 
cause loss of system functionality and damage to property 
and / or  people.

The following symbols can be found in this manual:

Operating procedures are marked this way.

Consequences are presented this way.

Buttons

 or 

switches

 to be pressed / activated are shown 

in bold.

• “Indicators” are placed in quotation marks.

1.1.1 Validity of the manual

1.1.2 SIMON LINK

1.1.3 SIMON PLUS

1.1.4 M-SHEV ECO

1.2 Use for the intended purpose

The M-SHEV product family (Modular Smoke and Heat 
Exhaust Ventilation) consists of electrical control devices in a 
sheet steel housing with power supply, emergency power 
supply and complete control and regulation electronics for the 
operation of 24 V DC actuators. 

Ventilation signals from

• ventilation buttons
• wind / rain detectors

and alarm triggering of three monitored indicating lines

• emergency button 

(SHEV-emergency button )

• smoke / thermal detectors 
• fire alarm control system (FAS)

can be processed.

The M-SHEV modular control units control actuators both in 
the event of fire (as smoke and heat extraction systems) and 
for daily ventilation. In the event of a power failure, the 
emergency power supply ensures the function of the SHEV 
system for at least 72 hours.

INFORMATION

An information text gives you additional hints!

ATTENTION

This warning notice alerts you to potential hazards that 
may impact the product!

DANGER

This warning notice alerts you to potential hazards to your 
life or health!

ENVIRONMENT NOTICE

This notice alerts you to potential environmental hazards!

INFORMATION

As of July 2019, this manual applies to M-SHEV control 
systems with firmware version from mid 2019 and 
SIMON LINK 2.2.0 or higher!

INFORMATION

Functions that can be configured or 
enabled with SIMON LINK are marked 
with the SIMON LINK logo!
You can find more information about 
SIMON LINK on our website 

short.simon-protec.com/slen

INFORMATION

SIMON PLUS are extra features, available at an additional 
charge, which must be enabled ex works or on site by a 
SIMON service technician.
For more information, please contact our technical sales 
department.

INFORMATION

The here described factory configuration for control units 
of the ECO product class cannot be changed via 
SIMON LINK.
Status messages can be read out.

Summary of Contents for M-SHEV Series

Page 1: ...ily Copyright by SIMON PROtec Systems GmbH Subject to technical changes and errors All figures are exemplary Only valid with the supplementary sheet Safety instructions and warranty conditions Operati...

Page 2: ...0 2 4 6 Technical data ZI 100 ZI1 10 2 5 Sensor Interface SI 100 11 2 5 1 Trigger or indicating lines line monitored 11 2 5 2 Indicators 11 2 5 3 ALARM mode reset 11 2 5 4 DIP switches 11 2 5 5 Reset...

Page 3: ...time 17 2 7 3 Technical data MI 100 MI1 17 2 8 BUS Interface BI 100 optional 18 2 8 1 MODBUS 18 2 8 2 Digital inputs 18 2 8 3 Technical data BI 100 BI1 18 3 Mechanical connection 19 3 1 M SHEV 10 AP...

Page 4: ...gulation electronics for the operation of 24 V DC actuators Ventilation signals from ventilation buttons wind rain detectors and alarm triggering of three monitored indicating lines emergency button S...

Page 5: ...ties M SHEV 10 AP Dimensions W x H x D Weight including battery 14 3 kg Protection rating IP20 according to EN 60529 Housing Steel sheet powder coated Colour RAL 9010 Table 2 Mechanical properties M S...

Page 6: ...tching power supply charging device battery are used cascaded The following figures may vary depending on the size of the housing and number of modules According to EN 12101 10 both the primary switch...

Page 7: ...failure undervoltage of the power supply or if the primary power supply fails 2 1 4 Technical data rated values Table 6 Operating voltage continuous operation 230 V AC Permissible voltage range short...

Page 8: ...Fuse character type T 3 15 A Charging voltage 26 7 27 9 V DC Charging current 1 1 A Interruption time no interruption LED indicator for mains operating state Continuous green light mains present LED i...

Page 9: ...3 Internal BUS connection The individual modules of the M SHEV control panel are con nected to each other through the BUS connections RJ45 sockets 2 3 1 Terminal plugs AS 110 The AS 110 terminating pl...

Page 10: ...evaluat ed independently of each other as normally open or normally closed Two 24 V DC terminals mains backup are available to connect the inputs The respective functions are shown in the connection p...

Page 11: ...00 is provided with the following indicators Indicating line is triggered separate for B1 B2 and B3 red Failure faults of the SI 100 yellow OK operating state green 2 5 3 ALARM mode reset After a SI 1...

Page 12: ...0 SI1 Table 17 Permissible voltage range 21 28 2 V DC Power consumption standby mode 10 20 mA Power consumption ALARM mode max 80 mA Emergency button connection 7 terminals OK Y M RZ RA B1 Smoke detec...

Page 13: ...unction Basic The MR 120 module operates as standard with 3 priority levels for detection lines 1 HE button 2 smoke detector and 3 BMZ When an as signed sensor interface is triggered the MR 120 reacts...

Page 14: ...as long as the respective direction button is pressed The actuators stop as soon as the button is released If the ventilation button is touched only briefly the ventilation command is switched to cont...

Page 15: ...and closing times must be measured and then entered on site The connected actuators then move to the required position proportional to the applied supply voltage or current To ensure that this openin...

Page 16: ...ntacts A statement always consists of three elements a logical statement no entry statement is true or NOT the statement is negated the origin of the statement and the statement Origin of the statemen...

Page 17: ...ndition logical statement is true the dry contact relay is switched either as long as the condition remains true or for a preset time 1 second to 1 hour 2 7 2 c Hold time After reaching the condition...

Page 18: ...o set the parity stop bits and a watchdog function If the MODBUS communication is lost the BI 100 goes into fault mode 2 8 2 Digital inputs There are 2 digital inputs A 24 V DC terminal mains is avail...

Page 19: ...the housing s direct mounting points for the M SHEV see Figure 15 Mounting points back of housing or mount the four wall fixing lugs see Figure 16 Wall fixing lugs supplied to the housing and then ma...

Page 20: ...10 AP Figure 18 M SHEV DANGER The system must be mounted by specialist personnel qualified electricians only All relevant national safety regulations and directives apply to mounting installation and...

Page 21: ...h RM 2860 TH 4860 1 2 3 4 5 24V Wind Rain Digital Input GND E LZ A Z E 5 NO 1 2 3 NC Jumper Power Supply 4 e g central ventilation or other external control Mains Backup wind rain detector WTS OK Y M...

Page 22: ...formation for motor cable empirical formula Wire cross section mm single cable length m x number of actuators x current consumption per actuator A 73 The DIN VDE 0100 and DIN VDE 0298 regulations cont...

Page 23: ...rical fastening features i e it can be used on the right or left The lid can alternatively be equipped with a lock 5 2 M SHEV Place the pair of batteries on the bottom plate of the housing Connect the...

Page 24: ...51 379368 0 Fax 49 0 851 379368 70 SIMON PROtec Deutschland GmbH Fraunhoferstra e 14 82152 Planegg Martinsried Tel 49 0 89 79170 11 Fax 49 0 89 79179 72 E Mail info simon protec de Internet www simon...

Reviews: