EA-K-30 – Technical Data
Operating Manual
Chain actuator – EA-K-30/xxx-T(-DA)
Chain actuator
– EA230-K-30/xxx(-S)
BA_EA(230)-K-30-XXX_EN_12
www.simon-protec.com
Date: 13.02.2019
Issue: 1.2 / 01.2019
Page 24
7. EA-K-30 – Technical Data
Table 1: Electrical properties
Actuator type/version
EA-K-30
Rated voltage
Permissible rated voltage range
Ripple of the rated voltage Vpp
Undervoltage detection
Nominal current
1
1.
Maximum current consumption at nominal load
Maximum starting current in
“OPEN” and “CLOSED”
direction
Maximum cut-off current in
“OPEN” and “CLOSED”
direction, after start-up
2
2.
Can be configured via SIMON LINK.
soft - close current
3
3.
Soft - close range: last 75 mm before reaching the “CLOSED” end
position, soft - close current can be configured via SIMON LINK – current
range: 0.3 A – 1,0 A; when the speed reduction function is activated
0.3 A – 0.5 A.
Current consumption after cut-
off (closed current)
Cut-off via
Maximum permissible number
of actuator units connected in
parallel in tandem operation
4
4.
With a common cut-off function (tandem function).
Cable length between two
actuators in tandem operation
Tandem run-on time
5
5.
The tandem run-on time indicates how long the actuator connected in
parallel continues to run after cutting off the triggering actuator.
The run-on time is 3 s in each case 50 mm before reaching the end
position and 0 s in the range between (see Figure 10: “Configurable
ranges” on page 8).
Pulse time
6
6.
The pulse time indicates how long the internal or external overload cut-
off provides the cut-off signal at the output.
Protection class
Table 2: Dry contact (NO1, NO2)
Actuator type/version
EA-K-30
Rated voltage
Contact load relay
The normally open contact (NO) is only activated in the
“CLOSED” end position when the actuator is cut off. This
means that the message is stroke-dependent and can be
evaluated as a “CLOSED message”. Activation of the
actuator at the “OPEN” end position can also be configured
via SIMON LINK, as well as other settings.
Table 3: Connection and operation
Actuator type/version
EA-K-30
Silicone connection cable with
connector
Supply cable length
1
1.
Optional lengths possible.
Pause time at a change in the
driving direction
2
2.
It is necessary that the supply voltage ensures a pause time (zero volt
range) of at least 500 ms for a change in the driving direction (pole
reversal) (see Figure 29: “Zero volt range at a change in the driving
direction” on page 25).
Switch-on duration
S2 ED 30% (short-time duty
Stability of opening and closing
cycles
Sound level
3
3.
Measured at a distance of one metre under normal conditions.
Re-triggering in accordance
with prEN 12101-9
Re-triggering after a stop
Maintenance
24 V DC
24 V DC -15%; +15%
max. 500 mV
yes
1.0 A
1.1 A
1.1 A
0.3 A
40 mA
Integrated electronic overload
cut-off
2 in DUO operation
4 in parallel operation
(see chapter 6.2 “EA-K-30
Electrical connection” on
page 19)
max. 10 m
3 s
300 ms
III
max. 28 V DC
1.0 A
ATTENTION
The maximum load capacity of the contact must not be
exceeded (see Table 2: “Dry contact (NO1, NO2)”).
INFORMATION
The output of the dry contact occurs only on the gear side
of the actuator (see Figure 1: “EA-K-30/xxx-T(-DA) chain
actuator” on page 5)!
5 x 0.75 mm²
3 m
at least 500 ms
3 of 10 minutes)
11
000
≤
55 dB (A)
permitted
permitted
See chapter 11.1 “Care and
Maintenance” on page 28.