User manual for - FLOW METER SPI-N118
“F PrEc”
-
decimal point position
(precision of flow rate displaying). It can be set to:
“ 0”
“ 0.0”
“ 0.00”
“ 0.000”
“ 0.0000”
“0.00000”
Decimal point position is changed by
[^]
,
[v]
buttons.
Change of displaying precision can require appropriate correction of relays
thresholds and hysteresis. These parameters
are not
updated automatically, due to
settings of
“F PrEc” parameter.
“F unit”
- the unit of volume (cubic measure) used for flow rate displaying . It can be set to:
(
”lit.“
- litres, or
“m 3”
- cubic meters ). Units expressed by
“F unit”
,
“b unit”
and
“t unit”
are conventional, and can be exchanged to any other pair of units e.g. for
powders it can be
kilogram
and
tonne
.
“Ftunit”
- time unit used for flow rate displaying. It can be set to:
(
”SEC“
- seconds,
”min”
- minutes or
“hour”
- hours).
The unit used to displaying the flow rate, depend on parameters
“F unit”
and
“Ftunit”
simultaneously, for example: L/min or m
3
/h etc.
“F or P”
- type of value displayed on the display:
“FL vAL”
- flow value,
“PEriod”
- time per one unit of flow.
7.3.4.
“bAtCH” menu
This menu allows to configure total flow counter displaying mode.
“b PrEc”
-
decimal point position
(precision of batcher counter). It can be set to:
“ 0“
“ 0.0“
“ 0.00“
“0.000“
Decimal point position is changed by
[^]
,
[v]
buttons.
“b unit”
- the unit of volume (cubic measure) used for batcher counter displaying . It can be
set to: (
”lit.“
- litres, or
“m 3”
- cubic meters ).
Units expressed by
“F unit”
,
“b unit”
and
“t unit”
are conventional, and can be
exchanged to any other pair of units e.g. for powders it can be
kilogram
and
tonne
.
“CLrbAt”
- this option allows zeroing of batcher counter. After selection of this option ask
“CLEAr?”
is displayed. If user press
[ENTER]
batcher counter is cleared, else
action is cancelled.
29