User manual for - FLOW METER SPI-N118
Parameter
Description
Default value
User's value
Desc.
page
t PrEc
Precision of thresholds and hysteresis displaying
(while relay is controlled due to total flow counter
value)
0
t unit
The unit of thresholds and hysteresis displaying
(while relay is controlled due to total flow counter
value)
lit.
modE
Operation mode of relay
„in”
t on
Turn on delay of relay
0.0 (sec.)
t oFF
Turn off delay of relay
0.0 (sec.)
unit
Unit of
“t on”
,
“toFF”
parameters of relay
„SEC”
ALArmS
Reaction for critical situation of relay
„oFF”
Configuration of measurement input (”inPUt” menu)
PULSEL
Flow sensor factor (quantity of pulses per litre )
1.00
FrEq
Maximum input frequency
300 (Hz)
ZEro t
Maximum time between two following pulses
1.0 (sec.)
mEAS t
Width of
measurement window
0.5 (sec.)
Configuration of current flow display (“FLouu” menu)
F PrEc
Decimal point position (precision of flow rate
displaying)
0.0
F unit
The unit of volume (Cubic measure) for flow rate
displaying
lit.
Ftunit
The unit of time for flow rate displaying
min
F or P
Kind of value visible on the display
„FLvAL”
Configuration of Batcher Counter reset and displaying mode (”bAtCH” menu)
b PrEc
Decimal point position ( precision of batcher
counter displaying)
0.0
b unit
The unit of batcher counter displaying
lit.
E Clr
Active level/edge of batcher counter zeroing input
oFF
m CLr
Manual zeroing of total flow counter
oFF
A rES
Batcher autoreset function
oFF
Atunit
Time unit of autoreset delay
SEC
A dLy
Batcher autoreset delay
0
Configuration of Total Flow Counter reset and displaying mode (”totAL” menu)
t PrEc
Decimal point position ( precision of total flow
counter displaying)
0.000
t unit
The unit of total flow counter displaying
lit.
E Clr
Active level/edge of total flow zeroing input
oFF
45