10
dow contact can be connected to termi-
nals 3-4.
A type of electronic apparatus for the
control of civil plants via a telephone line
that can be pointed out is the model TEL
30.4 LANDIS & STAEFA.
3.7.3
Connection external temperature
sensor (fig. 14 pos. C)
The cables must be laid observing the safe-
ty low voltage specifications EN 60730. For
lengths up to 25 m use cables with sec-
tions of 0.25 square mm and for lengths
greater than 50 m use cables with sec-
tions of 0.5 square mm.
To have access to the connector of the
boiler (3) remove the cover of the control
panel and electrically connect the exter-
nal temperature sensor to the terminals
SE (8-9).
3.8
LOGICA REMOTE CONTROL
All the boiler's functions can be managed by
a optional digital multifunctional device code
8092204 for the remote of the boiler itself
and for regulating room climatic conditions
with an operational reserve of 12 hours.
The heating circuit is controlled by the room
temperature sensor built-in the equipment
or by the atmospheric conditions, with or
without environmental inflow, if the boiler is
connected to an external sensor.
Characteristics:
– Ergonomic control unit divided according
to function (control levels).
– Clear division of basic functions:
•
operating regime, correction of set
value and presence button are directly
accessible;
•
Dif fer ent r eal curr ent values ar e
accessible through the "info" button;
•
other functions can be programmed
after the cover has been opened;
•
special service level with protected
access;
– Each setting or modification is displayed
and confirmed.
– Tome setting (special line for changing
BST/CET).
– Heating programme with max. 3 heating
periods per day, individually selectable.
– Copy function for easy transfer of heat-
ing programme to the next or previous
day.
– Holiday programme: the programme is
interrupted for the holiday period and
automatically restar ted on returning
home.
– Option to return the heating program to
default values.
– Programming lock (child safety).
Functions:
– Delivery temperature control guided by
the atmospheric conditions, taking into
account the dynamics of the building.
– Delivery temperature control guided by
atmospheric conditions with influence of
ambient temperature.
– Ambient temperature control only.
– Adjustable influence of ambient tempera-
ture shift .
– Switch-on and switch-off optimisation.
– Rapid lowering.
– ECO functions (daily heating limiter, auto-
matic summer/winter switch-over).
– Controllable maximum C.H. flow temper-
ature limit (specifically for floor plants).
– Limitation of increase in pre-set C.H. flow
temperature.
– Anti-freeze protection for buildings.
– Hourly programming of the tank unit
temperature on two levels: comfort and
reduced.
– Domestic hot water control with nominal
value requirement and enable.
– Connection to room sensor or switching
of operating regime through the tele-
phone system with external contact or
through a window contact.
– Anti-bacterial.
3.8.1
Installation
The unit must be installed in the main living
room. For installation, follow the assembly
instructions inserted in the package. At this
point, with the selector knob on (
), the
installer can adjust the basic parameters set-
tings according to the individual needs (point
3.8.2).
If there is a thermostatic radiator
valve fitted, this must be set to maximum.
3.8.2Installation settings
The settings for the basic operating para-
meters for individual needs are reported in
the instruction leaflet supplied with the
"Logica Remote Control" and in the section
reserved for the user in this manual.
For further adjustments which can be car-
ried out by the installer, the "Logica Remote
Control" offers a level of service and para-
meterising which can only be accessed
through a special combination of buttons.
To activate this level of service or parame-
terising press buttons
and
at
least 5 seconds.
This will activate the parameterising level.
Then use the same arrow buttons to select
the individual input lines and adjust the val-
ues with
or
.
3.8.3
Gradient of the characteristic
heating curve
The gradient of the characteristic heating
curve is imposed on the current value
“15”
of Logica. Increasing the gradient as shown
Fig. 15