16
5 DESCRIPTION OF THE APPLIANCE
5.1
Characteristics
Edea T
are last generation condensing wall mounted boilers
which
Sime
has produced for heating and instant domestic
hot water production when combined with a storage tank. The
main design choices made by
Sime
for the
Edea T
boilers are:
– the total pre-mix microflame burner combined with a stain-
less steel heat exchanger with a plaster outer shell, for
heating
– room sealed, Type C appliance. Suitable for use on sealed
heating systems
– the electronic control and command circuit board with mi-
croprocessor, for optimal management of the heating sys-
tem and modulation of up to 1:10 for the instant produc-
tion of domestic hot water. It allows for connecting room
thermostats, an auxiliary sensor for managing kits, and the
external sensor. The presence of the external sensor will
make the boiler work at a variable temperature, in other
words, the temperature in the boiler will vary in relation to
the outdoor temperature, in accordance with the optimal cli-
matic curve selected during the installation phase, result-
ing in considerable energy and financial savings. Moreover,
the command board has an internal connection for inserting
an expansion board which is used to control external relays.
Other special features of the
Edea T
boilers are:
– the anti-freeze function which activates automatically if the
temperature of the water inside the boiler falls below the
threshold of the value set at parameter "PAR 10" and , if
there is an external sensor, if the external temperature falls
below the threshold of the value set at parameter "PAR 11"
– anti jamming function of the pump and diverter valve, this
activates automatically every 24 hours if no request for heat
has been made
– the chimney sweep function lasts 15 minutes and makes
the job of the qualified technician easier when measuring
the parameters and combustion efficiency
– screen display of the operating and self-diagnostic param-
eters with error code display when the fault occurs. This
makes repair interventions easier and allows appliance op-
eration to be restored correctly.
5.2
Check and safety devices
The
Edea T
boilers are equipped with the following check and
safety devices:
– thermal safety thermostat 100°C
– 3 bar relief valve
– heating water pressure transducer
– delivery sensor (SM)
– hot water tank sensor
– exhaust sensor (SF)
– return sensor (SR).
d
DO NOT
Do not commission or operate the appliance with
safety devices which do not work or which have been
tampered with.
a
WARNING
Safety device may only be replaced by professional
qualified personnel using
Sime
original spare parts.
5.3
Identification
The
Edea T
boilers can be identified by means of:
1 Packaging label:
this is located on the outside of the pack-
aging and provides a code, the serial number of the boiler
and the bar code.
2 Energy Efficiency Label:
this is positioned on the outside of
the packaging to notify the User of the level of energy sav-
ings and reduced environmental pollution produced by the
appliance.
3 Technical Data Plate:
this is located inside the front panel of
the boiler and provides the technical data, appliance per-
formance information and any other information required
by law in the country where the appliance will be used.
4 Steaker of product identification
.
1
3
1
I II
A
B
C
D
E
F
G
2015
811/2013
Cod. 6244745
dB
kW
A
++
A
+
A
B
C
D
E
F
G
2
3
2
4
4
Code
Model
Serial/N.
GC No
_ _ _ _ _ _
_ _ _ _ _ _ _ _ _ _ _ _ _
_ _ _ _ _ _ _ _
_ _ - _ _ _ - _ _
Fig. 10
m
CAUTION
Tampering with, removing or failing to display the
identification plate or carrying out any other oper-
ation which does not allow safe identification of the
product or which may hinder installation and main-
tenance operations.