Display of operating data and counters
Once the boiler is operating a qualified technician can view the
operating data and the counters as follows:>.
From the operating screen in the mode enabled at that mo-
ment (WINTER
n
or SUMMER
l
):
– turn the heating
t
and hot water
r
knobs to the minimum
– simultaneously
press
, for more than 3 s, the
>
and
<
but-
tons.
From this point, the technician has 2 options:
– pressing the
>
button will scroll the list of
“information
(PAR)”
and of the
“counters (PARc)”
. The scrolling sequence
is as follows
– pressing the
<
button will show the
“alarms occurred” (PARa)
– move within the displayed items using the
<
or
>
buttons
– once the desired values have been displayed, to exit the
menu press the
y
button until the home page appears.
TABLE OF INFORMATION DISPLAYED
Type
No. Description
Range
U/M
Step
PAR
00 SW version
PAR
01 External tempera-
ture sensor
- 9 ..
99
°C
1
PAR
02 Delivery sensor
temperature (SM)
- 9 ..
99
°C
1
PAR
03 Exhaust tempera-
ture (SF)
- 9 ..
99
°C
1
PAR
04
Domestic hot water
sensor temperature
(SS)
- 9 ..
99
°C
1
PAR
05 AUX auxiliary
sensor
- 9 ..
99
°C
1
PAR
06 Actual heating SET
temperature
Par. 13
… Par.
14
°C
1
PAR
07 Power level
0 .. 99
%
1
PAR
08 DHW Flow rate
0 .. 99
l/min
0.1
PAR
09 Water pressure
transducer reading
0 .. 99
bar
0.1
PAR
10 Actual speed fan
number
0 .. 99
RPM x
100
1
TABLE OF COUNTER DISPLAYED
Type
No. Description
Range
U/M
Step
PAR
c0 total no. of boiler
operating hours
0 .. 99
h x 1000
0.1; from
0.0 to 9.9;
1; from 10
to 99
PAR
c1 total no. of burner
operating hours
0 .. 99
h x 1000
0.1; from
0.0 to 9.9;
1; from 10
to 99
PAR
c2 total no. of burner
ignitions
0 .. 99
h x 1000
0.1; from
0.0 to 9.9;
1; from 10
to 99
PAR
c3 total no. faults
0 .. 99
x 1
1
PAR
c4
total no. of times
installer parame-
ters "ALL"accessed
0 .. 99
x 1
1
PAR
c5
total no. of times
OEM parameters
accessed
0 .. 99
x 1
1
PAR
c6 Countdown to the
next service
1 .. 199
months
1
TABLE OF ACTIVATED ALARMS/FAULTS
Type
No. Description
PAR
A0 Last activated alarm/fault
PAR
A1 Last but one activated alarm/fault
PAR
A2 Third from last activated alarm/fault
PAR
A3 Previous activated alarm/fault
PAR
A4 Previous activated alarm/fault
PAR
A5 Previous activated alarm/fault
PAR
A6 Previous activated alarm/fault
PAR
A7 Previous activated alarm/fault
PAR
A8 Previous activated alarm/fault
PAR
A9 Previous activated alarm/fault