96
007-4701-003
4: Installing and Removing Customer-Replaceable Units
4. Replace the lower PCI/PCI-X support bracket and screw in the four Phillips screws,
as shown in Figure 4-16.
Figure 4-16
Replacing the PCI/PCI-X Support Bracket
5. Replace the optional chassis rail (if applicable) as described in “Reinstalling the
Optional Chassis Rail” on page 79.
6. Close the top cover as described in “Closing the Cover” on page 80.
7. If your system uses optional slide rails, follow substeps a-d; otherwise go to step 8.
a.
Fully extend the left and right slide rails from the rack until they lock into place.
b. This step requires two people. With one person holding each side of the
module, align the chassis rails of the module with the slide rails of the rack.
c.
Slide the chassis rails into the slide rails until the chassis rails are stopped by the
safety latches.
d. Press the safety latches on both sides of the module, and slide the module into
the rack.