Operating the Server System
007-4566-001
61
Operating the Server System Modules via Front Panel Controls
The front panel of the base compute module, the system expansion compute module,
and the MPX module provides the following control features, as shown in Figure 1-33:
Note:
If your server system includes other modules such as the TP900 and the PCI
expansion module, see the operating instructions provided for those modules.
•
Status LEDs.
The front panel has the following LEDs:
•
Power button LED. This LED illuminates green when the internal components
are on.
•
Service-required LED. This LED illuminates yellow to indicate that an item is
not functioning properly (for example, a fan is off), but the server is still
operating.
•
Failure LED. This LED illuminates red to indicate that a failure has occurred
and the server is down.
•
Power button.
Press this button to power on the server. Alternatively, you can
power on the server system at a system console.
•
Reset button.
Press this button to reset the internal processors and ASICs. The reset
will cause a memory loss. (To perform a reset without losing memory, see the NMI
button information that follows.)
•
NMI button
. Press the NMI (non-maskable interrupt) button to reset the internal
processors and ASICs without losing memory. Register data and memory are stored
in a
/var/adm/crash
file.
Summary of Contents for Origin 350
Page 1: ...SGI Origin 350 Server System User s Guide 007 4566 001 ...
Page 3: ...007 4566 001 iii Record of Revision Version Description 001 June 2003 Original publication ...
Page 4: ......
Page 16: ......
Page 26: ......
Page 50: ...24 007 4566 001 1 Installation and Operation Figure 1 11 Location of Table mounting Feet ...
Page 90: ......
Page 158: ......
Page 180: ......
Page 228: ......
Page 262: ......
Page 274: ......