194
007-4566-001
6: Installing and Removing Customer-replaceable Units
6. Remove the plastic air baffle covering the DIMMs, as shown in Figure 6-29.
Figure 6-29
Removing the Plastic Air Baffle
7. Remove the DIMM, as follows (see Figure 6-30):
Note:
If you need to find the correct location from which to remove the DIMMs,
make sure to read the introductory material in “Memory” on page 186.
a.
Lift the two ejector latches simultaneously to disengage the DIMM from its
connector.
b. Carefully grasp the DIMM and pull it up and out of the guide rails.
Note:
Hold the DIMM only by its edges. Be careful not to touch its components
or gold edge connectors.
c.
Place the DIMM on an ESD-safe surface.
8. If you are installing a new DIMM, proceed to “Installing a DIMM” on page 189. If
you are not installing a new DIMM, proceed to the next step.
9. Replace the plastic air baffle.
10. Attach or close the hinged cover and secure it to the module with the ten Phillips
screws.
Air baffle