Recovering from a Drive Failure
0 0 7 - 5 5 3 3 - 0 0 1
71
To monitor the rebuild progress
, enter command
SHOW JOB * ALL_ATTRIBUTES
To show the storage pool information
, enter command
SHOW POOL <id>
ALL_ATTRIBUTES
. Once the rebuild is complete, the status of storage pool will return to
“NORMAL”.
4.4.2
Drive Replacement
Upon completion of a rebuild, the spare drive becomes a member of the storage pool, replacing the
failed drive. After you have replaced the failed drive with a new drive, the new drive is added to the
unassigned pool. It is recommended that you assign this new drive to the spare pool to “replace” the
spare drive that has been used.
4.4.3
Spare Not Available
When a drive is failed by the system and there is no spare drive available, you need to replace the
failed drive immediately. After you have replaced the failed drive with a new drive, you can initiate
a rebuild as described below:
1.
Enter command
SHOW UNASSIGNED_POOL * ALL
to identify the new drive’s index name.
2.
Enter command
ASSIGN PHYSICAL_DISK <new-disk-id> TO_POOL <pool-id>
SET_SPARE
where <new-disk-id> is the index name of the replacement drive and <pool-id> is
the OID of the storage pool that had the failed drive.
Figure 94. Display Rebuild Progress
RAID$ show job * all_attributes
OID: 0x2b050003
Target: 0x19b40003
Type: REBUILD
Status: RUNNING
Priority: 80
Fraction Complete:12%
Figure 95. Display Storage Pool Information
RAID$ show pool 3 all_attributes
OID: 0x19b40003
Type: STORAGE
Name: raid 5 set
Chunk Size: 64KB (0x80 blocks)
Block Size: 0x200
RAID Type: RAID5
Free Raid5 Capacity: 2752512 MBs
Total Capacity: 3522560 MBs
UUID: 0x00
Global Spare Pool: 0x1a0f000a
Initializing: FALSE
Rebuilding: TRUE
Paused: FALSE
AutoWriteLock: FALSE
Data Lost: FALSE
Current Home: 0x0015b2a122b20000 0x00000000
Future Home: 0xffffffffffffffff 0x00000000
Preferred Home: 0xffffffffffffffff 0x00000000
BkgdJob OID: 0x2b050003
BkgdJob Priority: 80%
Total Phy Disks 5
State: NOREDUNDANCY
Member Size: 704512 MB
pID State UUID
0x0191 RBLD 0x5000cca215c56e02
0x004e NORM 0x5000cca215c5709c
0x0040 NORM 0x5000cca215c54c71
0x0041 NORM 0x5000cca215c5675c
0x0042 NORM 0x5000cca215c56e55
...
Spare Drive Rebuilding
Summary of Contents for InfiniteStorage 6120
Page 1: ...SGI InfiniteStorage 6120 RAID User s Guide 007 5533 001 ...
Page 10: ......
Page 11: ...SECTION 1 Introducing the InfiniteStorage 6120 ...
Page 12: ......
Page 23: ...SECTION 2 InfiniteStorage 6120 Installation ...
Page 24: ......
Page 32: ......
Page 43: ...SECTION 3 InfiniteStorage 6120 Management ...
Page 44: ......
Page 66: ......
Page 68: ......
Page 69: ...SECTION 4 Supporting the InfiniteStorage 6120 ...
Page 70: ......
Page 85: ...SECTION 5 Appendices ...
Page 86: ......
Page 94: ......