Setting Up the InfiniteStorage 6120
0 0 7 - 5 5 3 3 - 0 0 1
20
2.2.3
Connecting the InfiniteStorage 6120
2.2.3.1
Host Connections
Each InfiniteStorage 6120 supports up to four Fibre Channel host connections, two per controller.
Each connection is auto-sensing and supports 2 Gb/s, 4 Gb/s or 8 Gb/s. You may connect more than
four hosts to the unit using a Fibre Channel switch (not provided).
The host ports are numbered as shown in
below. Connect your switch or host system(s) to
these ports.
2.2.3.2
Expansion Enclosure Connections
A expansion enclosure can be daisy-chained to the InfiniteStorage 6120 to increase storage capacity.
Follow these steps to connect an expansion enclosure:
NOTE :
Only a 60-drive expansion enclosure can be used with the InfiniteStorage 6120
for storage expansion.
1.
Using the supplied mini-SAS connector, connect one end of the cable to the port labeled
EXPANSION
on the InfiniteStorage 6120 controller
2.
Connect the other end of the cable to the port labeled
EXP2
on the expansion enclosure
.
3.
Repeat for the second controller
.
Figure 18. A Controller
EXPANSION
CLI
LINK
SPEED
PO
R
T
2
PORT 1
Host Port 1
Host Port 2
CLI Connector
Firmware Status LED
Power LED
Expansion Port
(DO NOT USE)
Figure 19. I/O Module on Expansion Enclosure
EXP 2 Port
HOST1
EXP 1
HOST 2
EXP 2
Figure 20. Daisy-Chaining
InfiniteStorage 6120
Expansion Enclosure
Summary of Contents for InfiniteStorage 6120
Page 1: ...SGI InfiniteStorage 6120 RAID User s Guide 007 5533 001 ...
Page 10: ......
Page 11: ...SECTION 1 Introducing the InfiniteStorage 6120 ...
Page 12: ......
Page 23: ...SECTION 2 InfiniteStorage 6120 Installation ...
Page 24: ......
Page 32: ......
Page 43: ...SECTION 3 InfiniteStorage 6120 Management ...
Page 44: ......
Page 66: ......
Page 68: ......
Page 69: ...SECTION 4 Supporting the InfiniteStorage 6120 ...
Page 70: ......
Page 85: ...SECTION 5 Appendices ...
Page 86: ......
Page 94: ......