42
Chapter 3: Operating the Storage System
Getting Information About Other Components
For state information on other components—field-replaceable units—in the
CHALLENGE RAID storage system besides disk modules, use
raid5
-d device
getcrus
A sample output of this command follows:
FANA State: Present
FANB State: Present
VSCA State: Present
VSCB State: Present
VSCC State: Present
SPA State: Present
SPB State: Present
BBU State: Present
Note:
In this output, information on the power supplies is shown under
VSC
(voltage semi-regulated converter), SP information is shown under
SP
, and
battery backup unit information is shown under
BBU
.
Bind Signature
Unique value assigned to each disk in a logical unit at bind time
Hard Read Errors
Number of hard errors encountered on reads for this disk
Hard Write Errors
Number of hard errors encountered on writes for this disk
Soft Read Errors
Number of soft errors encountered on reads for this disk
Soft Write Errors
Number of soft errors encountered on writes for this disk
Read Retries
Number of retries occurring during reads
Write Retries
Number of retries occurring during writes
Remapped Sectors
Number of sectors that have been remapped
Number of Reads
Number of reads this disk has seen
Number of Writes
Number of writes this disk has seen
Table 3-2
(continued)
Output of raid5 getdisk
Output
Meaning