94
Appendix A: Technical Specifications
Table A-2 summarizes specifications for the rack storage system.
Physical
Dimensions
Minimum chassis weight
Maximum chassis weight
Disk drive module
Third power supply
module
Second storage-control
processor
Battery backup unit
Height: 62.9 cm (24.75 in)
Width: 35.6 cm (14.0 in)
Depth: 76.2 cm (30.0 in)
Chassis with 5 disk modules, 1 SP,
2 VSCs, without packaging: 51.6 kg
(114.0 lb)
Chassis with 20 disk modules, 2
SPs, 3 VSCs, BBU, without
packaging: 83.9 kg (184.5 lb)
1.6 kg (3.5 lb)
2.4 kg (5.3 lb)
1.2 kg (2.6 lb)
5.4 kg (12 lb)
Service clearance
Front
Rear
81.3 cm (32.0 in)
81.3 cm (32.0 in)
Buses
External host bus
Internal storage system
buses
Differential fast and wide SCSI-2
(synchronous)
Five single-ended SCSI buses
Table A-2
CHALLENGE RAID Rack Specifications
Classification
Specification
Value
AC power
requirements
Cabinet voltage
Current draw per chassis
assembly
Power consumption
200 VAC to 240 VAC, single-phase 47 Hz to
63 Hz
5.0 A max at 200 VAC input
(20.0 A max for 4 chassis assemblies)
Apparent power: 1000 VAC max
True power: 980 W max
Connector
Type
Domestic: L6-30P/L6-30R
International: IEC Plug 309 2-P
Table A-1 (continued)
CHALLENGE RAID Deskside Chassis Specifications
Classification
Specification
Value