![Silego GreenPAK SLG46140 Manual Download Page 25](http://html.mh-extra.com/html/silego/greenpak-slg46140/greenpak-slg46140_manual_1270947025.webp)
000-0046140-111
Page 24 of 169
SLG46140
5.8 ACMP Specifications
Table 12. ACMP Specifications
Symbol
Parameter
Description/Note
Conditions
Min.
Typ.
Max.
Unit
V
ACMP
ACMP Input Voltage
Range
Positive Input
VDD = 1.8 V ± 5 %
0
--
V
DD
V
Negative Input
0
--
1.1
V
Positive Input
VDD = 3.3 V ± 10 %
0
--
V
DD
V
Negative Input
0
--
1.2
V
Positive Input
VDD = 5.0 V ± 10 %
0
--
V
DD
V
Negative Input
0
--
1.2
V
V
offset
ACMP Input Offset
Voltage
Low Bandwidth -
Enable, Vhys = 0 mV,
Gain = 1,
Vref = (50..1200) mV,
VDD = (1.71..5.5) V
T = 25°C
-10.2
--
9.0
mV
T = (-40..85)°C
-15.3
--
13.4
mV
Low Bandwidth -
Disable, Vhys = 0 mV,
Gain =1,
Vref = (50..1200) mV,
VDD = (1.71..5.5) V
T = 25°C
-6.8
--
6.3
mV
T = (-40..85)°C
-7.2
--
6.6
mV
t
start
ACMP Start Time
ACMP Power On
delay, Minimal
required wake time for
the “Wake and Sleep
function”, Regulator
and Charge Pump set
to automatic ON/OFF
BG = 550 μs,
T = 25°C
VDD = (1.71..5.5) V
--
406.7
1735.7
µS
BG = 550 μs,
T = (-40..85)°C
VDD = (1.71..5.5) V
--
468.3
4411.9
µS
BG = 100 μs,
T = 25°C
VDD = 2.7..5.5 V
--
157.3
507.5
µS
BG = 100 μs,
T = (-40..85)°C
VDD = 2.7..5.5 V
--
171.2
1402.1
µS