LANCER PLUS
Operating manual
12
Copyright Silca 1998
5.2
Checking DEPTH CALIBRATION
DEPTH CALIBRATION for lever cuts (ø 80 mm cutter)
Position the main carriage on the left hand side (position
1
- fig. 12 on page 13) and install the
setting tools (X) into the jaws.
Check that the setting tools (X) touch simultaneously cutter and tracer. If it does not occur:
- loosen the grub screw (V) and turn clockwise or anti-clockwise the (K) knurled knob until the setting
tools align with cutter and tracer. Lock the grub screw (V).
Fig. 10
DEPTH CALIBRATION for side wards cuts (ø 25 mm cutter)
Position the main carriage on the left hand side (pos.
- fig. 12) to install the setting tools (X) into the jaws.
To calibrate the ward cutter, position the carriage on the right hand side (position 2).
Check that the setting tools (X) touch simultaneously cutter and tracer. If it does not occur:
- loosen the knob (L) and loosen grub screw (L1).
- turn clockwise or anti-clockwise the (I) knurled knob until the setting tools align with cutter and tracer.
- after correctly calibrating the tracer it is necessary to locate and lock the setting ring (L2) against the
body of the tracer. Lock knob (L).
Fig. 11
X
X
V
K
I
L
L1
L2
X
X