LANCER PLUS
Operating manual
Copyright Silca 1998
11
5
CHECKING CALIBRATION
The LANCER PLUS is calibrated in the Silca factory before dispatch but it’s recommended to check
before operating.
It’ also recommended to carry out these operations when fitting new cutters or tracer points.
5.1
Checking AXIAL CALIBRATION
AXIAL CALIBRATION for LEVER CUTS
Position the main carriage on the left hand side (position
1
- fig. 12 on page 13) to install the setting tools
(X) into the jaws.
If it does not occur:
- loosen the two allen screws (M1) and move laterally the tracer until it is aligned with the setting tools.
Fig. 8
AXIAL CALIBRATION for SIDE and BULLET WARDS
Position the main carriage on the left hand side (position
1
- fig. 12 on page 13) to install the setting tools
(X) into the jaws.
To calibrate the ward cutter, position the carriage on the right hand side (position 2 - fig. 12).
Check that the setting tools (X) align correctly on the right hand side of the cutter and tracer (fig. 9). If it
does not occur:
- loosen the two allen screws (N1) and move laterally the tracer until it is aligned with the setting tools
(X).
Fig. 9
M1
X
X
N1
X
X