Wiring Examples
In the following sub chapters, wiring examples are provided. It must be ensured that all
constructive measures etc. are complied with and applied in order to fulfill the requirements
of the category used.
9.1
Performance Level e, Category 4 or SILCL 3
– Safety PLC
To meet the requirements of category 4, performance Level "e" for EN ISO 13849-1 and
SILCL 3 according to EN / IEC 62061, two error-proof output of a Safety PLC must be used.
Cross-circuit detection between the two lines via the output tests of the STO 081 is hereby
possible.