S-DIAS AXIS MODULE
DC 061-1
23.08.2019
Page 25
5.2.2
Wiring AKM Motors with Molex Connectors
With Holding Brake
Length
M061E-10-1-015-3-0
1.5 m
M061E-10-1-030-3-0
3.0 m
M061E-10-1-050-3-0
5.0 m
M061E-10-1-100-3-0
10.0 m
Without Holding Brake
Length
M061E-10-0-015-3-0
1.5 m
M061E-10-0-030-3-0
3.0 m
M061E-10-0-050-3-0
5.0 m
M061E-10-0-100-3-0
10.0 m
The Shielding/PE connections of the motor cable, as well as the encoder cable
shielding must be grounded via the 6.3 mm blade receptacle provided on the respec-
tive cables. With increased interference, it may be necessary to also connect the
motor and encoder cable on the motor side.
If the Molex connector could experience strain during use, it must be equipped with
proper strain relief directly before and after the connector.
5.2.3
Wiring AKM Motors with Y-Tec
With Holding Break
Length
M061E-10-1-015-1-0
1.5 m
M061E-10-1-030-1-0
3.0 m
M061E-10-1-050-1-0
5.0 m
M061E-10-1-100-1-0
10.0 m