S-DIAS AXIS MODULE
DC 061-1
23.08.2019
Page 35
9.2
Performance Level e, Category 3 & SILCL 3
– Safety PLC
To meet the requirements of safety category 3, performance level "e" for EN 13849-1 and
SILCL 3 according to EN / IEC 62061, an error-proof output of a safety PLC must be used.
The reason of category 3 here, is that cross-circuit detection between the two lines is not
possible.