DC 061-1
S-DIAS AXIS MODULE
Page 28
23.08.2019
6
Motor Overload Protection
Equipment does not incorporate motor overload protection. External or remote overload
protection in accordance with National Electrical Code and any additional local codes must
be provided in the field.
7
Safety Conformity
7.1
Functional Safety Standards
-
EN / IEC 62061:2005/A2 2015
-
EN ISO 13849-1:2015
-
EN ISO 13849-2:2012
7.2
EU Conformity Declaration
CE Declaration of Conformity
The DC 061-1 complies with the following European directives:
•
2006/42/EG “Directive of the European Parliament and of the
Council of 17 May 2006 on Machinery and Change to the Directive
95/16/EC” (machine guideline)
•
2014/30/EU “Electromagnetic Compatibility” (EMC guideline)
•
2011/65/EU Restricted use of certain hazardous substances in
electrical and electronic equipment (RoHS Guideline)
The EU Conformity Declarations are provided on the SIGMATEK website.
Using the search function with the keyword “EU Declaration of Conformity”.
7.3
Safety-Relevant Parameters
DC 061-1
Safety Parameters
Safety Levels
Safety function STO
PFH
D
= 4.98E-10 (1/h)
MTTF
D
= 4651 years
DC = 99.27 %
SFF = 99.87 %
SIL 3 resp. SILCL
according to EN/IEC 62061
PL e / Cat. 4
according to EN ISO 13849-1/-2
Summary of Contents for DC 061-1
Page 15: ...S DIAS AXIS MODULE DC 061 1 23 08 2019 Page 13...
Page 17: ...S DIAS AXIS MODULE DC 061 1 23 08 2019 Page 15 3 Mechanical Dimensions...
Page 24: ...DC 061 1 S DIAS AXIS MODULE Page 22 23 08 2019 5 Wiring 5 1 Wiring Example...
Page 36: ...DC 061 1 S DIAS AXIS MODULE Page 34 23 08 2019...
Page 38: ...DC 061 1 S DIAS AXIS MODULE Page 36 23 08 2019...
Page 40: ...DC 061 1 S DIAS AXIS MODULE Page 38 23 08 2019...
Page 42: ...DC 061 1 S DIAS AXIS MODULE Page 40 23 08 2019...