The following checks should be carried out before leaving the site;
Check the cabinet door seals are intact and in the correct positions. Replace as necessary ensuring
the surface is clean before fitting.
If appropriate (when using a Standard Controller Stool) inspect the cabinet base seal. If damaged,
the affected area should be filled with sand and re-sealed. For details see the Controller Stool
Installation Method Statement (667/CC/53060/000).
Routine Setup Check
Check that the real time clock is set correctly.
A true measurement of the accuracy of the real time clock can only be gained if the clock with
which it is compared has been accurately set up.
It is essential that the time be compared with an adjacent controller using a clock that has been
synchronised to that controller within the last 30 minutes.
Other Maintenance Operations
The following maintenance procedures may also be required and are described elsewhere in this
document.
•
RTC battery replacement - see section 6.9.2
•
Addition & removal of licences - see section 6.9.7
•
Loading new IC4 configuration - see section 6.9.3
•
Loading of new Plus
+
Site Layout Design
–
see section 6.9.4
•
Update of firmware - see section 6.9.6
•
Export of site information - see section 6.9.15