ST950 Plus+ User Manual
ST950 Plus+ User Manual
Page 127 of 176
667/HE/53000/000
Issue 2
Unrestricted
The time mode, date and time can be set from the web page:
Status and Configuration → Controller → Clocks
The user should configure the controller clocks as required - refer to the Time section in the ST950
Facilities Handbook 667/HB/46000/001 and then set the time and date as follows:
•
Enter the current date in the 'Set Date' box using one of the accepted formats
•
Enter the time to be set in the 'Set System Time' and / or 'Set Controller Time' (depending on
the clock system required) in one of the accepted formats
•
Press the 'Save' button at the precise time set.
System Time : Stratos Connection
It is not necessary to set the System time when the profile is set to
Stratos
.
System Time : Stratos Connection
It is not necessary to set the System time when the profile is set to
Stratos
.
System Time : NTP
If NTP is used, the time may not be the actual time but that used by the system (In-Station
time)
System Time : CLF Plans
If CLF plans are to be used it is important that the clock be set accurately to ensure that the
plans operate as expected.
The Handset can also be used to set the Real Time Clock using Level 3 access and the 'TOD='
command, for example:
'TOD=21AUG13' to set the Date and
'TOD=10:36:00' to set the time