Technical data
11.1 Technical data
SITRANS SL
186
Operating Instructions, 12/2010, A5E01132948-04
Safety
Electric safety
In accordance with IEC 61010 / DIN VDE 0411
Protection against explosion
ATEX II 2 G Ex de op is IIC T6
ATEX II 2 D Ex tD A21 IP 65 T85 °C
FM:
- Explosionproof for Class I, Division 1, Groups A, B, C and D,
Temperature Class T6 Ta=55 °C;
- Flameproof for Class I, Zone 1, AEx d IIC,
Temperature Class T6 Ta=55 °C;
- Dust-ignitionproof for Class II/III, Division 1, Groups E, F and G,
Temperature Class T6 Ta=55 °C;
- Dust-tight for Zone 21, AEx tD T85 °C Ta=55 C;
indoors and outdoors (Type 4X/IP65)
The information provided in this chapter contains descriptions or characteristics of
performance which in case of actual use may not apply as described as a result of further
development of the product. Technical specifications are subject to change without further
notice.