Technical data
11.1 Technical data
SITRANS SL
182
Operating Instructions, 12/2010, A5E01132948-04
Design, enclosure
Design, enclosure
Degree of protection
IP65 in accordance with EN 60529
Dimensions
For each unit (transmitter, receiver)
Diameter: 165 mm
Length 357 mm
Purging tube
Length: 340 mm
Outer diameter: ∅ 48 mm
Inner diameter: ∅ 44 mm
Weight
Receiver unit 6.0 kg
Transmitter unit 5.2 kg
Process interface
–
For DN50/PN 10-40 5.3 kg
–
For ANSI4"/150 lbs. approx. 12 kg
Connection dimension
customer flange
DN 50/PN 10-40 or ANSI 4"/150 lbs
Electric characteristics
Power supply
24 V DC nominal (18 ... 30.2 V DC)
Maximum power consumption
10 VA
EMC immunity
In accordance with EN 61326-1
Electric safety
In accordance with EN 61010-1
External fuse specifications
T1.6L250V
Dynamic performance
Warm-up time at 20 °C/68 °F
ambient temperature
Start of measurement: < 5 min.
Full gas measurement accuracy: < 60 min.
Response time (T
90
)
Approx. 2 s, depending on application
Integration time
0 ... 100 s, selectable