![Siemens SITRANS F C MASSFLO series Operating Manual Download Page 30](http://html.mh-extra.com/html/siemens/sitrans-f-c-massflo-series/sitrans-f-c-massflo-series_operating-manual_1265486030.webp)
Modbus RTU RS-485
30
SFIDK.PS.023.D2.02
APPENDIX C
17 (0x11) Report slave ID
Query
Slave address
1 byte
Function
1 byte
CRC
2 bytes
Slave address
1 byte
Function
1 byte
17 (0x11)
Byte count
1 byte
52 (0x34)
Slave ID
1 byte
0x2a = Siemens
Run indicator
1 byte
0 = Off, 0xFF = Running
Product code
1 byte
24 = MAG 6000, 25 = MASS 6000
Transmitter Code No.
9 bytes
e.g. „083H0222“
Capability bits
3 bytes
0x01, 0xFF, 0x00
Manufacturer name
12 bytes
„Siemens“
Product name
18 bytes
„MAG 6000“ or „MASS 6000“
Flowmeter major rev.
1 byte
e.g. 2
Flowmeter minor rev.
1 byte
e.g. 1
Modbus module name
11 bytes
„Modbus RTU“
Modbus major rev.
1 byte
e.g. 1
Modbus minor rev.
1 byte
e.g. 0
CRC
2 bytes
Response
Examples
Read report slave ID
Query:
1,11,c0,2c
Receive:
1,11,2a,ff,19,30,38,33,48,30,32,32,32,0,1,ff,0,53,69,65,6d,65,6e,73,0,0,0,0,0,
4d,41,53,53,36,30,30,30,0,54,0,0,2,1,4d,4f,44,42,55,53,20,52,54,55,
0,ff,1,2,3f,98
Address
=
1
Function code
=
17
Byte Count
=
55
Slave ID
=
0x2A
Run Indicator
=
0xFF
Product Code
=
25 (0x19)
Transmitter Code No.
=
083H0222
Capability bits
=
0x01, 0xFF, 0x00
Manufacturer name
=
Siemens
Product name
=
MASS 6000
Product major rev.
=
2
Product minor rev.
=
1
Modbus module name
=
Modbus RTU
Modbus module No.
=
0xFF
Modbus module major rev.
=
1
Modbus module minor rev.
=
2
CRC LO
=
0x3f
CRC HI
=