![Siemens SITRANS F C MASSFLO series Operating Manual Download Page 22](http://html.mh-extra.com/html/siemens/sitrans-f-c-massflo-series/sitrans-f-c-massflo-series_operating-manual_1265486022.webp)
Modbus RTU RS-485
22
SFIDK.PS.023.D2.02
Modbus
Modbus
No. of
Data
Read/
register
address
bytes
type
Description
write
4:02501
2500
20
String
Converter type
R
4:02511
2510
20
String
Converter code no.
R
4:02521
2520
20
String
Converter serial no.
R
4:02531
2530
20
String
Converter SW version
R
4:02541
2540
20
String
Sensor type
R
4:02551
2550
20
String
Sensor code no.
R
4:02561
2560
20
String
Sensor serial no.
R
4:02571
2570
20
String
Sensor size
R
MAG 6000
6.
Modbus holding registers
Modbus
Modbus
No. of
Data
Read/
register
address
bytes
type
Description
write
4:02501
2500
20
String
Converter type
R
4:02511
2510
20
String
Converter code no.
R
4:02521
2520
20
String
Converter serial no.
R
4:02531
2530
20
String
Converter SW version
R
4:02541
2540
20
String
Sensor type
R
4:02551
2550
20
String
Sensor code no.
R
4:02561
2560
20
String
Sensor serial no.
R
4:02571
2570
20
String
Sensor size
R
4:02581
2580
20
String
Customer code no.
R
MASS 6000
Modbus
Modbus
No. of
Data
Read/
register
address
bytes
type
Description
write
4:02701
2700
4
Double word
Operating time (s)
R
4:02703
2702
54
Byte array
Error pending list
See appendix B
R
4:02730
2729
54
Byte array
Error log list
See appendix B
R
MAG 6000
Modbus
Modbus
No. of
Data
Read/
register
address
bytes
type
Description
write
4:02701
2700
4
Double word
Operating time (s)
R
4:02703
2702
54
Byte array
USM II Error pending list
See appendix B
R
4:02730
2729
54
Byte array
USM II Error log list
See appendix B
R
4:02757
2756
4
Float
Driver signal (A)
R
4:02759
2758
4
Float
Pickup 1 amplitude (V)
R
4:02761
2760
4
Float
Pickup 2 amplitude (V)
R
4:02763
2762
4
Float
Sensor frequency (Hz)
R
MASS 6000
6.9
Product identity
6.10 Service info