Modbus RTU RS-485
16
SFIDK.PS.023.D2.02
Modbus
Modbus
No. of
Data
Read/
register
address
bytes
type
Description
write
4:02001
2000
2
Byte
Flow direction:
0 = Negative
R/W
1 = Positive
4:02002
2001
4
Float
Massflow max. (kg/s)
R/W
4:02004
2003
4
Float
Volumeflow max. (m
3
/s)
R/W
4:02010
2009
4
Float
Density min. (kg/m
3
)
R/W
4:02012
2011
4
Float
Density max. (kg/m
3
)
R/W
4:02014
2013
4
Float
Sensor temperature min. (
°
C)
R/W
4:02016
2015
4
Float
Sensor temperature max. (
°
C)
R/W
4:02018
2017
4
Float
Fraction A max. (kg/s)
R/W
4:02020
2019
4
Float
Fraction B max. (kg/s)
R/W
4:02022
2021
4
Float
% fraction A min. (1/100 %)
e.g. value 0.05 = 5 %
R/W
4:02024
2023
4
Float
% fraction A max. (1/100 %)
e.g. value 0.8 = 80 %
R/W
4:02026
2025
4
Float
Low flow cut off:
(1/100 %)
e.g. value = 0,02 = 2 %
R/W
4:02028
2027
4
Float
Empty pipe limit (kg/m
3
)
R/W
4:02030
2029
2
Byte
Empty pipe on/off:
0 = Off
R/W
1 = On
4:02031
2030
2
Byte
Noise filter:
1 = min.
2
3
R/W
4
5 = max.
4:02032
2031
2
Byte
Error level:
1 = Warning
2 = Permanent
R/W
3 = Fatal
4:02033
2032
2
Byte
Zero adjust mode:
0 = Auto
R/W
1 = Manual
4:02034
2033
4
Float
Manual zero adjust (kg/s)
R/W
4:02036
2035
2
Word
Zero adjust time (s)
R/W
4:02037
2036
4
Float
Zero sigma (kg/s)
R
4:02039
2038
4
Float
Zero sigma limit (kg/s)
R/W
MASS 6000
6.
Modbus holding registers
Modbus
Modbus
No. of
Data
Read/
register
address
bytes
type
Description
write
4:02001
2000
2
Byte
Flow direction:
0 = Negative
R/W
1 = Positive
4:02006
2005
4
Float
Q max. (m
3
/s)
R/W
4:02008
2007
4
Float
Q max. 2 (Night) (m
3
/s)
R/W
4:02026
2025
4
Float
Low flow cut off:
e.g. value 0,02 = 2 %
R/W
4:02030
2029
2
Byte
Empty pipe on/off:
0 = Off
R/W
1 = On
4:02032
2031
2
Byte
Error level:
1 = Warning
2 = Permanent
R/W
3 = Fatal
4:02033
2032
2
Byte
Zero adjust mode
1)
:
0 = Auto
R/W
1 = Manual
4:02034
2033
4
Float
Manual zero adjust
1)
(ms/s)
R/W
4:02041
2040
2
Byte
Mains Frequency
0 = 50 Hz
R/W
1 = 60 Hz
MAG 6000
6.4 Basic settings
1)
Only available in MAG 6000 SV