Installation
50
Siemens Building Technologies
Fire Safety & Security Products
02.2009
8.4.14 SISTORE unit – CKA4820 – SISTORE RemoteView – LAN cameras
Fig. 31
SISTORE MX – CKA4820 – SISTORE RemoteView – LAN cameras
system overview
1
CKA4820 optional
2
SISTORE unit
3
Client PC with RemoteView
4
SISTORE MX: max. 64 LAN cameras
SISTORE MX 3G: max. 16 LAN cameras
various manufacturers
For a more detailed description of the connections please refer to Section
183H
6
184H
Description of SISTORE
MX / MX DVD or Section
185H
7
186H
Description of SISTORE MX 3G / MX 3G DVD.
Prerequisite:
z
The CKA driver is installed and the icon
is displayed in the task bar. See
Section
187H
9.3
188H
Subsequent installation of software components.
1.
Connect the CKA4820 control panel to the SISTORE (see
189H
Fig. 31).
2.
Configure COM1B on the control panel as an RS485 interface.
Further information on this can be found in the instruction manual for the
control panel.
3.
Start the SISTORE MX application software.
4.
Switch to configuration mode.
5.
Select the
System
tab.
6.
Mark the checkbox
CCTV keyboard
. Further information on this can be found
in the SISTORE MX Configuration Manual.
Î
The interface for the control panel is enabled.
Connections
Signal SISTORE
unit
9-pin Sub-D socket
CKA4820
9-pin Sub-D plug
A (Rx/Tx +)
2
5
B (Rx/Tx -)
3
9
GND 5
6