Installation
48
Siemens Building Technologies
Fire Safety & Security Products
02.2009
8.4.12 Connecting Miniter interface and access reader
Fig. 29
System overview: SISTORE MX – interface und access reader (Miniter)
A
Cable (9-pin), plug-plug
2-3, 3-2
B
Null-modem cable (9-pin), plug-plug
2-3, 3-2, 4-6, 5-5, 6-4, 7-8, 8-7
For a more detailed description of the connections please refer to Section
173H
6
174H
Description of SISTORE
MX / MX DVD or Section
175H
7
176H
Description of SISTORE MX 3G / MX 3G DVD.
1.
Connect the interface to the SISTORE (see
177H
Fig. 29).
For this you require the converter 485SD9R (B&B), a 9-pin cable, Sub-D,
plug-plug, connections 2–3, 3–2, and a null-modem cable, Sub-D, plug-plug,
connections 2–3, 3–2, 4–6, 5–5, 6–4, 7–8, 8–7.
2.
Connect pin 7 of the Sub-D connector through an 81-Ohm resistor to 12 V.
See the figure below:
1
Pin 7
2
+12 V
3.
Connect the access reader (Miniter) to the interface.
4.
Start the SISTORE MX application software.
5.
Switch to configuration mode.
6.
Select the
System
tab.
7.
Mark the checkboxes
Bank mode
and
Cash dispenser
.
8.
Click
Apply
.