Additional information for additional ports (bottom side of device, front, port B)
Zusatz
DNP3.0, optical, 820 nm, ST connector
+ L 0 H
IEC 60870-5-103, redundant, electrical RS485, RJ45 connector
+ L 0 P
IEC61850, 100Mbit Ethernet, 2 electrical ports, RJ45 connector
+ L 0 R
IEC61850, 100Mbit Ethernet, 2 optical ports, LC-duplex- connector
+ L 0 S
Converter
Order number
Use
SIEMENS OLM
1)
6GK1502–2CB10
for single ring
SIEMENS OLM
1)
6GK1502–3CB10
for double ring
1)
The converter requires an operating voltage of 24 VDC. If the available operating voltage is > 24 VDC the additional
power supply 7XV5810–0BA00 is required.
Additional communication interfaces for port A (bottom side of device, rear)
Pos. 12
no additional
1)
0
Redundant optical fiber protection interface to 2-wire protection interface
Protection interface optical fiber for monomode (24 km) (14.9 mi.)/multimode fiber (4 km) (2.5 mi.), LC
duplex connector
2)
7
1)
Already equipped with optical fiber protection interface if MLFB pos. 6 = 1,2,5 or 6
2)
Deliverable only in combination with 6th position = 3 or 7
Measurement / Fault Recording
Pos. 13
With fault recording
1
With fault recording, average values, min/max values
3
Protection functions
Pos. 15
ANSI-Nr
Description
Basic design (included in all versions)
A
87L/87N L
Line differential protection (phase comparison and 3I0 differential protection)
1)
Inrush current detection
50 TD/51
Overcurrent protection phase 50-1, 50-2, 50-3, 51
50N TD/51N
Overcurrent protection ground 50N-1, 50N-2, 50N-3, 51N
49
Thermal overload protection (49)
74TC
Trip circuit supervision
50BF
Circuit-breaker failure protection
86
Lock out
Circuit breaker transfer trip
External trip initiation
Cold load pickup (dynamic setting changes)
Monitoring functions
Circuit breaker test
Circuit breaker control
Flexible protection functions from current, voltage, power
2)
27/59
Undervoltage/overvoltage 27, 59
2)
81 U/O
Underfrequency / overfrequency
2)
Basic directional overcurrent protection phase and directional ground fault protection
1)
3)
B
67
Overcurrent protection, directional phase ∠(V,
Ι
) 67-1, 67-2, 67-TOC
67N
Ground fault protection, directional ∠(V,
Ι
) 67N-1, 67N-2, 67N-TOC
Basic ground fault differential protection in resonant-grounded/isolated systems
3)
4)
C
87Ns L
Ground fault differential protection in resonant-grounded/isolated systems
Ordering Information and Accessories
A.1 Ordering Information 7SD80 V4.7
SIPROTEC 4, 7SD80, Manual
301
E50417-G1100-C474-A2, Edition 02.2018
Summary of Contents for SIPROTEC 4 7SD80
Page 8: ...8 SIPROTEC 4 7SD80 Manual E50417 G1100 C474 A2 Edition 02 2018 ...
Page 10: ...10 SIPROTEC 4 7SD80 Manual E50417 G1100 C474 A2 Edition 02 2018 ...
Page 18: ...18 SIPROTEC 4 7SD80 Manual E50417 G1100 C474 A2 Edition 02 2018 ...
Page 248: ...248 SIPROTEC 4 7SD80 Manual E50417 G1100 C474 A2 Edition 02 2018 ...
Page 298: ...298 SIPROTEC 4 7SD80 Manual E50417 G1100 C474 A2 Edition 02 2018 ...
Page 312: ...312 SIPROTEC 4 7SD80 Manual E50417 G1100 C474 A2 Edition 02 2018 ...
Page 322: ...322 SIPROTEC 4 7SD80 Manual E50417 G1100 C474 A2 Edition 02 2018 ...
Page 400: ...400 SIPROTEC 4 7SD80 Manual E50417 G1100 C474 A2 Edition 02 2018 ...
Page 402: ...402 SIPROTEC 4 7SD80 Manual E50417 G1100 C474 A2 Edition 02 2018 ...