Table 1-2
Ambient conditions during storage and transport
Type of condition
Permissible range/class
Transport
Storage
Classification
EN 60721-3-2
EN 60721-3-1
Climate class
2K4
1K4
Ambient temperature
1)
-40° C ... +70° C
-25° C ... +55° C
Biological environmental condi‐
tions
2B1
2)
1B1
2)
Chemically active environmental
conditions
2C2
3)
1C2
3)
Maximum permissible tempera‐
ture change
Direct interaction in air/air:
-40°/+30° C at 95% relative
humidity
30 k/h
Relative humidity (without conden‐
sation)
5 to 95%
Precipitation, rain
6 mm/min
2)
Not permissible
Water other than rain
1 m/s and wet loading surfa‐
ces
4)
Not permis‐
sible
5)
1 m/s and wet
loading surfaces
4)
Height
Max. 4,000 m above sea level
Condensation, splash water,
icing, salt spray
Permissible
Not permis‐
sible
5)
Permissible
4)
1)
Transport and storage of operator panel fronts and diskette drives: -20° C to +55° C.
2)
Mold growth, slime, rodents, termites and other animal vermin are not permissible.
3)
In marine- and weather-resistant transport packaging (container).
4)
For storage in the transport packaging.
5)
For storage in the product packaging.
Note
Remove the transport protective foil and packaging material before installing the components.
Shipping backup batteries
Backup batteries must only be shipped in the original packaging. No special authorization is
required to ship backup batteries. The lithium content is approximately 300 mg.
Note
The backup battery is classified as a hazardous substance, Class 9 in accordance with the
relevant air-freight transportation regulations.
Storage of backup batteries
Always store backup batteries in a cool and dry place. The batteries have a maximum shelf
life of 10 years.
General information and networking
1.2 Application planning
Operator panel front: OP 010
Manual, 07/2018, A5E36371538B
15