maxhostindex=2 /* Number of nodes that are defined under
[host_1] and [host_2].
mcpIndex=192
tcuIndex=1
eksIndex=0
[host_1]
Address=192.168.214.1 /* Address of the NCU to which the
connection is established during booting.
[host_2]
Address=157.163.230.202 /* Address of the PC
password=123456 /* Password of the VNC server on the PC
Switching over between the nodes
With the "Menu back" + MENU SELECT keys, the following actions are triggered:
● In the header of the displayed window you will see the TCU name, for example TCU1.
● A selection list for connecting to the other nodes will be displayed on the TCU.
See also
Settings in the "config.ini" file (Page 63)
1.4.3.5
Application example
Application
The configuration is suitable for the following application: Machine with concurrent operating
option to two operator panels , a full-featured operating panel with PCU and an operator panel
reduced to tool management.
Parallel operation of HMI-Advanced or SINUMERIK Operate on the PCU 50.3 and
SINUMERIK Operate as component of the CNC software on the SINUMERIK 840D sl NCU:
Any OP connected to PCU 50.3 and any OP connected to the NCU can be simultaneously
operated: in the example, OP 08T.
General information and networking
1.4 Networking
Operator panel front: OP 010
84
Manual, 07/2018, A5E36371538B