3. Scroll in the right window area to "PasswordOptions".
– Set the properties for the password.
– Click on the "UPDATE" button to save the changes.
4. Perform a restart so that the settings are accepted.
Configuring blocking rules for users
Here, you can define the following settings, for example:
Blocking rule
Settings
AllowedForNewUsers
Defines as to whether new users can be locked out
true
New users can be locked out.
DefaultLockoutTimeSpan
Defines the time interval for which a user is locked out, for
example: after an incorrect login attempt.
Example:
In minutes:
"DefaultLockoutTimeSpan": {
"Minutes": 5
},
In hours, minutes and seconds:
"DefaultLockoutTimeSpan": {
"Hours": 0,
"Minutes": 5,
"Seconds": 30
},
MaxFailedAccessAttempts
Defines the number of unsuccessful attempts before a user is
locked out.
e.g.
3
Configuring the settings
6.1 Configuration using the "Consul" software
Manage MyResources, Optimize MyProgramming /NX-Cam Editor
Installation Manual, 12/2019, A5E44672080B AE