Technical data
7.7 Technical data, 690 V inverters
Power Module PM240-2
Hardware Installation Manual, 01/2017, A5E33294624B AE
91
Table 7- 27 PM240-2, IP20, frame size E, 3 AC 500 V … 690 V
Article number - without filter
Article number - with filter
6SL3210-1PH25-2UL0
6SL3210-1PH25-2AL0
6SL3210-1PH26-2UL0
6SL3210-1PH26-2AL0
LO base load power
45 kW
55 kW
LO base load input current
50 A
59 A
LO base load output current
52 A
62 A
HO base load power
37 kW
45 kW
HO base load input current
44 A
54 A
HO base load output current
42 A
52 A
Siemens fuse according to IEC/UL
Fuse according to IEC/UL, Class J
3NA3824-6 (80A)
80 A
3NA3824-6 (80A)
80 A
Power loss without filter
1.07 kW
1.30 kW
Power loss with filter
1.08 kW
1.31 kW
Required cooling air flow
83 l/s
83 l/s
Weight without filter
26 kg
26 kg
Weight with filter
28 kg
28 kg
Table 7- 28 PM240-2, IP20, frame size F, 3 AC 500 V … 690 V
Article number - without filter
Article number - with filter
6SL3210-1PH28-0UL0
6SL3210-1PH28-0AL0
6SL3210-1PH31-0UL0
6SL3210-1PH31-0AL0
6SL3210-1PH31-2UL0
6SL3210-1PH31-2AL0
LO base load power
75 kW
90 kW
110 kW
LO base load input current
78 A
97 A
111 A
LO base load output current
80 A
100 A
115 A
HO base load power
55 kW
75 kW
90 kW
HO base load input current
66 A
85 A
106 A
HO base load output current
62 A
80 A
100 A
Siemens fuse according to IEC/UL
Fuse according to IEC/UL, Class J
3NA3830-6 (100 A)
100 A
3NA3132-6 (125 A)
125 A
3NA3136-6 (160 A)
150 A
Power loss without filter
1.37 kW
1.74 kW
1.95 kW
Power loss with filter
1.38 kW
1.76 kW
1.97 kW
Required cooling air flow
153 l/s
153 l/s
153 l/s
Weight without filter
60 kg
60 kg
60 kg
Weight with filter
64 kg
64 kg
64 kg
Summary of Contents for SINAMICS PM240-2
Page 1: ......
Page 2: ......
Page 8: ...Table of contents Power Module PM240 2 8 Hardware Installation Manual 01 2017 A5E33294624B AE ...
Page 104: ...Spare parts Power Module PM240 2 104 Hardware Installation Manual 01 2017 A5E33294624B AE ...
Page 143: ......
Page 144: ......