Case 3: Filtered - for residential, commercial and light industry
This level of performance will allow the manufacturer / assembler to self-certify
compliance of their apparatus with the EMC directive for the residential,
commercial and light industrial environment as regards the EMC performance
characteristics of the power drive system. Performance limits are as specified in
the generic emission and immunity standards EN 50081-1 and EN 50082-1.
Table 9-4
Case 3 - Filtered for Residential, Commercial and Light Industry
EMC Phenomenon
Standard
Level
Radiated Emissions *
EN 55011
Level for equipment Class B
Emissions
Conducted Emissions
EN 61800-3
Category C1: level equivalent to EN55011,
Class B
Category C2: level equivalent to EN55011,
Class A
Supply Voltage Distortion
EN 61000-2-4
Voltage Fluctuations, Dips,
Unbalance, Frequency
Variations
EN 61000-2-1
Electrostatic Discharge
EN 61000-4-2
8 kV air discharge
Immunity:
Burst Interference
EN 61000-4-4
2 kV power cables (Level 3), 2 kV control
(Level 4)
* These limits are dependent on the inverter being correctly installed inside a
metallic switchgear enclosure. The limits will not be met if the inverter is not
enclosed.
NOTE
To achieve these performance levels, you must not exceed the default Pulse
frequency.
Summary of Contents for SINAMICS G110
Page 1: ...Operating Instructions Edition 04 2005 sinamics SINAMICS G110 ...
Page 10: ...Safety Instructions 04 2005 SINAMICS G110 Operating Instructions 10 6SL3298 0AA11 0BP0 ...
Page 14: ...Overview 04 2005 SINAMICS G110 Operating Instructions 14 6SL3298 0AA11 0BP0 ...
Page 72: ...Options 04 2005 SINAMICS G110 Operating Instructions 72 6SL3298 0AA11 0BP0 ...
Page 86: ...List of Abbreviations 04 2005 SINAMICS G110 Operating Instructions 86 6SL3298 0AA11 0BP0 ...
Page 90: ......
Page 91: ......