Mounting
4.10 Mount the oil expansion unit
SIMOTICS S-1FG1 servo geared motor
Operating Instructions, 07/2019, A5E47360747B AA
103
4.10
Mount the oil expansion unit
The oil expansion unit equalizes changes in the oil volume caused by temperature
fluctuations in operation.
The oil expansion unit is required
●
at high input speeds
●
in mounting position M4 (motor top)
The size of the supplied oil expansion unit depends on the gearbox.
Table 4- 20 Oil expansion units and corresponding gearboxes
Unit size
Size 1
Size 2
Unit volume
0.05 l
1.5 l
Gearbox size
FZ 39 - 89
K 39 - 109
B 39 - 49
C 69 - 89
FZ.129
K 129 - 149
Note
Selecting the oil expansion unit
Contact the Siemens Service Center for final selection of the oil expansion unit.
The unit is supplied as a mounting kit.
Note
Attaching the oil expansion unit before commissioning
Before commissioning the gearbox, replace the pressure vent valve that is already installed
with the provided oil expansion unit.
Summary of Contents for SIMOTICS S-1FG1
Page 1: ...SIMOTICS S 1FG1 servo geared motor ...
Page 2: ......
Page 140: ...Faults SIMOTICS S 1FG1 servo geared motor 138 Operating Instructions 07 2019 A5E47360747B AA ...
Page 168: ......
Page 170: ......