"RF680M" software
9.5 The functions in the "Tag" menu
SIMATIC RF680M Mobile Reader
68
Operating Instructions, 06/2011, J31069-D0241-U001-A2-7618
Select "Tag > Lock Tag..." for this purpose. The following window is displayed.
Figure 9-10 Lock Tag
In the "Mask" line, you can select the following transponder-specific memory areas:
● "Kill": Kill Password
● "Acc": Access Password For memory areas EPC, TID and user memory
● "EPC": EPC memory
● "TID": TID memory
● "Usr": User memory
"Lock"
The entries under "Mask" determine which function is executed in the action area.
0
The action will not be executed
1
The action will be executed
Line
Kill PWD
Access PWD
EPC memory
TID memory
User memory
Mask
0/1
0/1
0/1
0/1
0/1
0/1
0/1
0/1
0/1
0/1
Action
r/w
p
r/w
p
w
p
w
p
w
p
The entry in the "Action" line specifies how the associated memory area will be locked.
● The identifier "r/w" defines password protection for reading/writing
● The identifier "w" defines password protection for writing (reading is permitted)
● The identifier "p" specifies permanent locking
All the possible combinations of "r/w", "w" and "p" are listed in the table below complete with