The software "RF-MANAGER"
8.3 Application mode "Mobile"
SIMATIC RF680M Mobile Reader
40
Operating Instructions, 06/2011, J31069-D0241-U001-A2-7618
Figure 8-5
"Read All" button
Note
ID check
It is checked for all tags before any read or write procedure whether the tag ID displayed in
the editor corresponds to the ID of the tag that is located in the field of the SIMATIC
RF680M. If this is not the case, time-out will be displayed after 20 seconds.
See also
Settings (Page 75)
8.3.2.3
Writing to the tag
Write tag data
If you click the "Write" button in the data editor (or press <Ctrl+W>), you can write the data
that is currently displayed in the editor to the tag.
"Write" button
Writing the data area of a tag
In the data editor, you can select the required memory area of the tag in which you want to
write data, and reduce it, if required, by removing the check mark from "Complete" and
entering the address and length in the respective fields.