The software "RF-MANAGER"
8.2 Application mode "Remote"
SIMATIC RF680M Mobile Reader
32
Operating Instructions, 06/2011, J31069-D0241-U001-A2-7618
8.1.6
Enter the IP address in the mobile reader
If a DHCP server is not present in the network, you must enter the IP address of
SIMATIC RF680M in the SIMATIC RF680M mobile reader:
1.
Double-click the WLAN icon in the taskbar for this purpose.
2.
In the "IP Information" tab, click the "Configure" button and select "Specify an IP
address". Enter the IP address.
As an alternative, you can also enter the IP address as follows:
1.
"Start > Settings > Control Panel > Network and Dial-up Connections" and select the
relevant connection.
2.
In the "IP Information" tab, click the "Configure" button and select "Specify an IP
address". Enter the IP address.
8.1.7
Creating a back-up
Create a back-up to save the settings even in the case of power failure. The steps you have
to perform to do this are described in detail in the section
Performing a back-up.
See also
Performing a back-up (Page 21)
8.2
Application mode "Remote"
In application mode "Remote" that is configured via the Engineering System in
RF-MANAGER, the SIMATIC RF680M mobile reader has the properties of a stationary
reader. This means that the acquired data are only displayed on the reader and transferred
to RF-MANAGER.
You are not able to acknowledge or reject the acquired data in SIMATIC RF680M.
8.2.1
Acquire data and transfer it to RF-MANAGER
Data acquisition
Depending on the configuration in the Engineering System, you can activate a barcode or
RFID read using the hardware keys or the "Scan" button of SIMATIC RF680M.
If you have configured the reading of barcodes, the acquired barcode will be preceded by
"BAR".
If you have configured the reading of RFID tag data, the acquired tag ID will be preceded by
"RFID".